KESTREL RIDGE · UNIT 2 MAIN CONTROL ROOM · PWR 3411 MWt
AT POWER SIMULATION
00:00:00 MODE 1 · POWER OPERATION
← EXIT
REACTORPRIMARY SYSTEM
NEUTRON FLUX100.0%
STARTUP RATE0.00DPM
ROD BANK D AUTO 164STEPS
T HOT323.5°C
T COLD290.5°C
T AVG / T REF307.0/ 307.0
PEAK CLAD345°C
SUBCOOLING21.2°C
PZR LEVEL60%
VESSEL LEVEL100%
DECAY HEAT6.5% · 222 MWt
RCS FLOW 100 % RCP ARCP BRCP CRCP D
PLANT MIMICONE OF FOUR COOLANT LOOPS SHOWN
TRENDSLAST 4 MINUTES ON SCREEN
TURBINE & GRIDSECONDARY SYSTEM
GENERATOR1150MWe
TURBINE LOAD100%
STEAM PRESS6.90MPa
SG LEVEL50%
FEED FLOW100%
STEAM DUMP0%
CONDENSER5.1kPa
TURBINE1800RPM
CNTMT RAD0.02mSv/h
CNTMT H₂0.0%
GRID 345 kV DG A STBY DG B STBY DC 100%
EVENT LOGnewest first

Nuclear Reactor Control Room Simulator — Fake Meltdown Screen

This page turns your browser into the main control room of a nuclear power station. A live diagram shows the reactor, the steam generator, the turbine, and the cooling tower with coolant moving through them. Dial gauges and readouts track power, temperature, and pressure, a wall of alarm tiles lights up when something goes wrong, trend charts draw the last four minutes, and an event log records what the plant and the crew are doing. You can run the plant calmly for hours, follow the grid up and down, trip a coolant pump, or run a station blackout through to core damage. You can also take the controls: SCRAM the reactor, drive the rods, restart pumps, and, if you are quick enough, save the core. Click ⛶ FULLSCREEN and it fills the screen.

Is any of it real?

No. Everything on the screen is simulated. Kestrel Ridge Unit 2 is an invented 1,150-megawatt pressurised-water reactor, and the crew, the grid dispatcher, and every reading are generated by a small model in your browser. Nothing is fetched from a utility, a regulator, or a plant computer. The model is deliberately simple and game-like: it gets the direction and rough size of things right, but it is not a training simulator and must not be used to learn how to operate, assess, or explain the behaviour of any real plant.

What's on the screen

Scenarios

The SCENARIO menu (or keys 1–4) picks what happens on its own. Every scenario loops, so the screen can be left running indefinitely.

Normal Operation
The default. The unit holds full power, the crew logs routine checks, and every minute or so something small happens: a charging pump swaps over, a circulating water pump trips and the condenser pressure creeps up, or the grid frequency rises and the turbine governor sheds a little load.
Load Follow
The grid dispatcher asks for different outputs between 50 and 100 percent. The turbine ramps to each new level and the automatic rod control drives the rods to keep the coolant temperature on its program. Watch the steam pressure rise as the load falls.
Coolant Pump Trip
A reactor coolant pump trips at full power. Flow in that loop coasts down, the core outlet temperature climbs, and within a couple of seconds the protection system trips the reactor on low flow. The plant settles in hot standby on decay heat, the pump is restarted, the reactor is brought back to power, and a while later another pump trips.
Meltdown
A station blackout. Offsite power is lost, one diesel generator fails to start and the other trips, and the steam-driven feed pump keeps the core cool until it fails too. The steam generators boil dry, the relief valve lifts, sticks open, and the reactor coolant boils away until the core uncovers, the cladding oxidises, and the end screen reads CORE DAMAGE. Forty-five seconds later the plant resets and the scenario starts again.

Operator controls

The OPERATOR buttons along the bottom work in every scenario.

To save the core in the Meltdown scenario, wait for the log to report that diesel generator B has restarted. The safety injection pumps start, but the pressurizer level reads off-scale high and the crew throttles them back, which is the same mistake made at Three Mile Island. The SAFETY INJ button lights up. Press it before the cladding reaches 1,850 °C and the core refills, the temperatures fall, and the plant reaches SAFE SHUTDOWN. In an escape room, that makes a natural final puzzle.

The Meltdown scenario, step by step

Times are plant time after the loss of offsite power, at normal speed with no operator action. The plant clock runs faster than real time once the reactor is shut down and the plant is waiting on decay heat, so the whole sequence plays out in about six minutes.

Plant timeEventWhat happens
0:00:00Loss of offsite powerThe grid connection is lost. The coolant pumps coast down, the reactor trips, and the turbine trips.
0:00:09Diesel A failsEmergency diesel generator A cranks but does not start.
0:00:26Station blackoutDiesel B starts, then trips on low lube oil pressure. Only the batteries are left.
0:00:32Steam-driven feed pumpThe turbine-driven auxiliary feed pump, which needs no AC power, keeps the steam generators fed. Natural circulation carries decay heat out of the core.
0:40:00Feed pump tripsThe turbine-driven pump trips on overspeed and will not reset. There is now no way to feed the steam generators.
about 1:07Steam generators dryWith no water on the secondary side, the reactor coolant has nowhere to put its heat and starts to warm up.
about 1:25Relief valve sticks openPressure reaches 16.2 MPa and the pressurizer relief valve lifts. On its third lift it fails to reseat, though its indicator says closed. Pressure falls until the coolant boils.
about 1:50Diesel B backDiesel B restarts. Safety injection starts, but the pressurizer level reads off-scale high, so the crew throttles it back. This is the window to press E.
about 2:24Core uncoveryThe water level falls below the top of the fuel. The core exit thermocouples read superheated steam.
about 2:52OxidationAbove roughly 1,000 °C the zirconium cladding reacts with steam, releasing heat and hydrogen. Past 1,204 °C, the regulatory cladding limit, the reaction runs away.
about 2:57Core damageThe cladding reaches 1,850 °C, about where zirconium alloy melts. The end screen comes up.

How a pressurised-water reactor works

A nuclear power station is a steam plant with an unusual boiler. The heat comes from fission: when a uranium-235 nucleus absorbs a neutron it splits into two lighter nuclei, releases about 200 MeV of energy, and throws out two or three new neutrons. Most of that energy appears as the fission fragments slamming into the surrounding fuel, which heats it. If on average exactly one of the new neutrons goes on to cause another fission, the chain reaction is steady and the reactor is critical. More than one and the power rises; fewer and it falls.

Fast neutrons from fission are poor at splitting uranium-235, so they have to be slowed down first. In a pressurised-water reactor (PWR) the cooling water does that job too: it is the moderator. The fuel is uranium oxide enriched to a few percent uranium-235, pressed into pellets and sealed in thin zirconium alloy tubes called cladding. About fifty thousand of these rods, bundled into assemblies, make up the core.

Power is controlled by absorbing neutrons. Control rods made of materials such as silver-indium-cadmium or boron carbide slide down into the assemblies from above. Driving them in absorbs more neutrons and lowers the power; withdrawing them raises it. Day to day, PWRs also dissolve boric acid in the coolant and adjust its concentration, which acts as a slow, even control across the whole core. Because water is also the moderator, the reactor regulates itself: if the water gets hotter it expands, moderates less well, and the power falls back. That negative temperature feedback is why the simulated plant settles down on its own after most disturbances.

The water that passes through the core is the primary loop. It leaves the reactor at about 325 °C, far above its normal boiling point, and stays liquid because the pressurizer keeps the whole loop at about 15.5 MPa, more than 150 times atmospheric pressure. Large pumps drive it through the steam generators, where it flows through thousands of U-shaped tubes and gives up its heat before returning to the reactor at about 290 °C. On the outside of those tubes is the secondary loop, at much lower pressure, where feedwater boils into steam. The two loops never mix, which keeps radioactive coolant inside the containment building.

The steam drives a turbine and generator, then condenses back to water in the condenser, which is cooled by a third loop of river, sea, or cooling-tower water. The clouds over a cooling tower are clean water vapour from that third loop. Only about a third of the reactor's heat becomes electricity, which is why a 3,400-megawatt thermal reactor produces around 1,150 megawatts of electric power.

Why SCRAM, and why the heat doesn't stop

A SCRAM, or reactor trip, is an emergency shutdown. The rods are held up by electromagnets or latches, and opening the trip breakers lets gravity drop every rod into the core in about two seconds. The protection system does this on its own whenever a reading crosses a limit: neutron flux too high, coolant pressure too high or too low, coolant flow too low, a steam generator too empty. The word dates from the first reactors of the 1940s; the popular explanation that it stands for "safety control rod axe man" is probably a backronym.

A trip stops the chain reaction almost at once, but it does not stop the heat. The fission fragments left in the fuel are radioactive and keep decaying, and that decay heat is about 6 to 7 percent of full power at the moment of shutdown, around 1 percent after an hour, and still about half a percent after a day. Half a percent sounds small, but for a reactor of this size it is still about 15 megawatts, and 1 percent is enough to boil off tens of tonnes of water an hour. That is why every PWR has several independent ways to keep cooling the core after shutdown, and why losing all of them, as in the Meltdown scenario, is so serious. Watch the DECAY HEAT readout after a SCRAM: the neutron flux collapses by orders of magnitude, but the decay heat creeps down only slowly.

What "meltdown" actually means

"Meltdown" is not an engineering term. Engineers talk about core damage: the fuel overheats because the heat is not being carried away, usually because the water covering it has boiled off or drained away. Once the top of the core is in steam instead of water, it heats up quickly. Above roughly 1,000 °C the zirconium cladding starts to react with the steam. That reaction releases heat of its own and produces hydrogen, and by about 1,200 °C it can generate more heat than the decay heat itself. Regulators set a limit of 1,204 °C (2,200 °F) on cladding temperature in accident analyses for that reason. Zirconium alloy melts at around 1,850 °C and the uranium oxide fuel at around 2,800 °C. Molten fuel and structural metal can slump to the bottom of the vessel as a mixture called corium.

A reactor cannot explode like a nuclear weapon. Its fuel is far too dilute for that. The dangers of core damage are the release of radioactive material if the containment fails, hydrogen explosions, and steam explosions, which is why containment buildings are thick steel-lined concrete and why many plants have hydrogen recombiners or igniters and filtered vents.

Three accidents shaped how the world thinks about this. At Three Mile Island Unit 2 in Pennsylvania in 1979, a pressurizer relief valve stuck open after a feedwater problem. Its indicator showed the signal sent to the valve, not the valve's real position, so the operators believed it was shut. Because the pressurizer level read high, they also cut back the emergency injection. About half the core melted, but the containment held and the off-site release was small. At Chernobyl in 1986, a graphite-moderated RBMK reactor of a very different design, which could gain power as its coolant boiled, ran away during a test, and a steam explosion and graphite fire spread contamination across Europe. At Fukushima Daiichi in 2011, an earthquake and tsunami took out offsite power and then the emergency diesels and much of the DC power, three boiling-water reactors suffered core damage, and hydrogen explosions wrecked three reactor buildings. The Meltdown scenario here borrows the station blackout from Fukushima and the stuck valve and throttled injection from Three Mile Island, on an invented plant with invented timings.

How to read a control room

Annunciator
A panel of backlit alarm windows. Real ones follow a fixed sequence: a new alarm flashes and sounds the horn, the operator presses acknowledge to make it steady and silent, and it goes dark when the condition clears. Here the crew acknowledges anything still flashing after about ten seconds.
SCRAM / reactor trip
All control rods inserted at once to shut down the chain reaction. Automatic trips come from the reactor protection system; a manual trip is a switch on the control board.
T hot, T cold, and T avg
Coolant temperature leaving the reactor, returning to it, and the average of the two. The rod control system moves the rods to keep T avg on a program (T ref) that rises from about 292 °C at no load to 307 °C at full load.
Subcooling margin
How far the hottest coolant is below its boiling point at the current pressure. When it reaches zero the coolant is boiling, which is a key warning sign in an accident.
PORV
Power-operated relief valve, on top of the pressurizer. It opens to vent steam to the relief tank when pressure gets too high and closes again when pressure falls. A PORV that sticks open is a small-break loss-of-coolant accident.
Vessel level
How much water is in the reactor vessel. Here 100 percent is full and the top of the fuel sits at 45 percent. Real plants added dedicated vessel level instruments after Three Mile Island, where the pressurizer level misled the crew.
Core exit thermocouples
Temperature sensors just above the fuel. A reading above about 650 °C means superheated steam is leaving the core and the core is not being cooled adequately. In a severe accident they read off scale.
Neutron flux and startup rate
Neutron flux is measured by detectors outside the vessel and tracks the fission rate. Startup rate, in decades per minute, says how fast it is changing: after a trip it settles near -1/3 DPM as the last delayed neutrons die away.
Steps
Control rod position counted in mechanism steps, here from 0 (fully inserted) to 228 (fully withdrawn).
Modes
Plant operating states in the technical specifications: Mode 1 power operation, Mode 2 startup, Mode 3 hot standby with the reactor shut down but the coolant hot and pressurised.
Station blackout
Loss of all AC power: offsite power and the emergency diesel generators. Only batteries and steam-driven pumps remain.
Emergency classes
US plants declare one of four levels: Notification of Unusual Event, Alert, Site Area Emergency, and General Emergency. The simulator escalates through them in a simplified way.

What the model simplifies

The neutron power follows the rod position and coolant temperature through a single lag, not the full point-kinetics equations with six groups of delayed neutrons. There is no xenon, no boron change during load follow, and one representative loop stands in for four. Decay heat follows a fitted version of the standard Way–Wigner curve, which is reasonably close. Most of the plant's numbers are typical of a large four-loop PWR, rounded. The biggest liberty is time: during load follow and startups the plant moves several times faster than a real one, and in the Meltdown scenario the clock is compressed by up to 45 times, which the TIME readout shows. Real operators train on full-scope simulators that copy one specific control room panel for panel, with models validated against the real plant. This is not one of those.

Good uses

Background screens for films, series, and music videos set in a power station or a disaster; stream and video backdrops for science and history content; escape rooms and tabletop games, where saving the core in the Meltdown scenario makes a ready-made final puzzle; classroom lessons on how a reactor makes electricity and why decay heat matters; and ambient displays for a themed event or an office. For OBS setup as a browser source, see the streaming toolkit. The alarm tiles pulse slowly, well under once a second, and there are no full-screen flashes; the accessibility notes cover the rest.

Keyboard shortcuts

Frequently asked questions

Is this a real nuclear plant?

No. Kestrel Ridge Unit 2 is invented, and every number on the screen comes from a small model running in your browser. Nothing is fetched from a utility, a regulator, or any plant computer, and the header says SIMULATION. It is a visual prop and a teaching aid, not a training simulator.

Is the meltdown scenario based on a real accident?

It borrows the general shape of real events without copying any one of them. The station blackout echoes Fukushima Daiichi in 2011, and the relief valve that sticks open while its indicator says closed, followed by a crew holding back injection because the pressurizer level looks high, echoes Three Mile Island in 1979. The plant, the timings, and the failures are made up.

Can I stop the meltdown?

Yes, if you are quick. Pumps and rods cannot help once the station has lost all AC power. When the log reports that diesel generator B has restarted and the SAFETY INJ button lights up, press E or click it to restore full injection flow before the cladding passes 1,850 °C. The core refills, the plant reaches SAFE SHUTDOWN, and the room resets.

How long does the meltdown scenario take?

About six minutes at normal speed: twenty seconds of normal operation, the blackout, the long boil-down, and core damage a little under three hours later in plant time. The plant clock runs up to 45 times faster than real time during the slow parts, and the TIME readout says so. The end screen stays up for 45 seconds, then the plant resets and the scenario runs again. The T key runs everything at 2× or 4×.

Can I use it in a video or on a stream?

Yes. It is free to use for videos, films, streams, escape rooms, classrooms, and signage. Click FULLSCREEN, or add the page as an OBS browser source. The scenario and speed are kept in the address bar, so a copied link reopens the same setup, and every scenario loops on its own, so it can run for hours.

Does it make any sound?

Only if you ask. The alarm horn is off when the page opens. Press M or click SOUND to turn it on, and the horn sounds while there are unacknowledged alarms, with a softer chime for warnings. Acknowledging the alarms with A silences it, and the crew acknowledges anything left flashing after about ten seconds.

Does it work offline?

Once the page has loaded, the simulation makes no further network requests, so it keeps running if the connection drops. The optional VIDEO view, when one is available, streams from YouTube and needs a connection.

Related tools

Fill the rest of the control room with the futuristic tech dashboard and the fake stock exchange screen, or move across the site to a different kind of console with the rocket launch simulator. When the plant's systems are supposed to have been hacked rather than broken, cut to the system breached screen.