Fake Heart Monitor Screen — ECG Patient Monitor Prop
This page turns your browser into a bedside patient monitor. A green ECG trace sweeps across a black screen with the pulse oximeter wave and the breathing wave underneath it, and the big numbers on the right show heart rate, oxygen saturation, blood pressure, breathing rate, and temperature. Pick a scenario and the rhythm and the numbers change the way they would on a ward: a racing heart, a slow one, atrial fibrillation, or a cardiac arrest that starts as ventricular fibrillation and decays to a flat line. Press S to shock the patient back. Click ⛶ FULLSCREEN and it fills the screen.
A prop, not a medical device
This is a simulation for film, video, games, and teaching. It is not medical equipment, and nothing on this page is medical advice.
Every waveform and number is generated in your browser from simple rules. Nothing is measured: there is no sensor, no camera, no microphone, and no connection to any device. The monitor (the XVM-7), the ward, the bed, and the patient are invented, and the screen says SIMULATION — NOT A MEDICAL DEVICE in the header at all times. Don't use it to watch over anyone or to check your own heart. If you are worried about your heart or someone else's, talk to a doctor, or call your local emergency number if it can't wait.
What's on the screen
- ECG (green): lead II, sweeping from left to right with a short gap, the erase bar, just ahead of the pen. Like a real monitor, each sweep overwrites the one before it instead of scrolling. The small bracket at the left edge is a 1 mV calibration mark.
- Pleth (cyan): the pulse wave from a finger clip. Each pulse arrives a fifth of a second or so after its heartbeat, because the pressure wave takes that long to reach the hand.
- Resp (yellow): breathing, drawn at a third of the ECG speed so several breaths fit on screen.
- HR: heart rate in beats per minute, averaged over the last few beats, with the rhythm name underneath and the alarm limits, 120 and 50, at the top right.
- SpO2: oxygen saturation in percent, with the pulse rate (PR) counted by the finger clip.
- NIBP: blood pressure from the arm cuff, systolic over diastolic with the mean in brackets. It measures every five minutes, a few seconds after each scenario change, and whenever you press N. While it measures, the number shows the cuff pressure as it inflates and then steps down.
- RR and TEMP: breaths per minute, and temperature in °C with °F underneath.
- Alarm bar: up to three messages at once, red for high priority, yellow for medium, and cyan for advisories, marked ***, ** and * as on many real monitors.
Scenarios
Choose one from the SCENARIO menu, with the keys 1–6, or with ?scenario= in the address bar. The numbers drift toward their new values over several seconds instead of jumping.
- Stable (1)
- Normal sinus rhythm around 74 bpm, SpO2 97–99%, blood pressure near 118/76, 15 breaths a minute, and 36.9 °C. The heart rate rises and falls slightly with each breath, as a healthy heart's does.
- Tachycardia (2)
- Sinus tachycardia around 140 bpm with a fever of 38.6 °C, faster breathing, higher blood pressure, and SpO2 around 94%. The HR HIGH and TEMP HIGH alarms come on.
- Bradycardia (3)
- Sinus bradycardia around 42 bpm with slightly low blood pressure. The HR LOW alarm comes on.
- AFib (4)
- Atrial fibrillation averaging about 115 bpm: no P waves, a wavering baseline, beats at irregular intervals, a pulse wave that changes height from beat to beat, and now and then a wide premature beat (PVC).
- Cardiac arrest (5)
- Coarse ventricular fibrillation for 30 seconds, fading to fine VF and then to asystole about 50 seconds in. The pulse wave goes flat at once, breathing stops after about eight seconds, and the next blood pressure attempt fails. The line stays flat until you shock or pick another scenario.
- Story loop (6)
- An eight-minute sequence for long recordings: stable, bradycardia, stable again, tachycardia, AFib, then 32 seconds of VF and an automatic shock that brings the patient back, before it starts over. It runs for as long as the tab is open.
Shocking the patient back
⚡ SHOCK (S) delivers a pretend 200-joule shock from whatever rhythm is on screen. The trace leaps off the top and bottom of its lane and drifts back to the baseline, the finger clip loses its signal for a moment, and the monitor returns to Stable. After an arrest the recovery is gradual: the heart restarts at about 100 bpm and settles, SpO2 climbs back from the low 80s over about half a minute, and a new blood pressure is taken 15 seconds later. Choosing a scenario from the menu skips the shock and changes the rhythm directly.
Shocking a flat line is a television habit. The section on the TV flatline below explains what a hospital would really do.
Sound
The monitor is silent until you press M or click ♪ SOUND OFF. A prop shouldn't make noise you didn't ask for, and browsers block page audio until you interact anyway. With sound on:
- A short beep plays on every R wave. Its pitch drops as SpO2 falls, as on many real monitors, so staff can hear a patient's oxygen falling without looking at the screen.
- High-priority (red) alarms play a burst of five quick tones every few seconds. Medium-priority (yellow) alarms play three slower tones.
- Asystole plays the steady flatline tone from films and television. Real monitors don't do this; they keep repeating the pulsed high-priority alarm.
- ALARM PAUSE (A) silences the alarm tones for two minutes, like the button on a real monitor. The heartbeat beep carries on and the alarm messages stay on screen.
Sound stops while the screen is frozen, while the tab is hidden, and while the video version is playing. For film work it is usually better to shoot the screen silent and add the beeps in the edit, so they don't sit under the dialogue.
How to read an ECG trace
An electrocardiogram records the tiny voltages the heart produces as an electrical wave spreads through it before each contraction. Electrodes on the skin pick up those voltages, and each lead is a view of the wave from a particular direction. Lead II, the one shown here and the default on most bedside monitors, looks from the right shoulder toward the left leg, roughly along the heart's own electrical axis, so its waves are usually upright and easy to see.
- P wave
- The small bump before each spike: the upper chambers, the atria, depolarise. That electrical signal is what makes them contract. A normal P wave lasts less than about 0.12 seconds.
- PR interval
- From the start of the P wave to the start of the spike, normally 0.12 to 0.20 seconds. It is the pause while the signal crosses the AV node, which gives the atria time to empty into the ventricles.
- QRS complex
- The tall, sharp spike: a small dip (Q), a tall upstroke (R), and a dip after it (S). The ventricles, the main pumping chambers, depolarise and contract. A normal QRS is narrower than 0.12 seconds. A wide one, like the PVCs in the AFib scenario, means the signal started in the ventricle and took the slow way around.
- ST segment
- The short, flat stretch after the spike. An ST segment raised above or pushed below the baseline can be a sign of a heart attack or a strained heart muscle, and doctors check it on a full 12-lead ECG rather than on one monitor lead.
- T wave
- The rounded bump after the spike: the ventricles repolarise, resetting for the next beat. The atria reset too, but their small wave is hidden inside the QRS.
- QT interval
- From the start of the QRS to the end of the T wave: the whole electrical cycle of the ventricles. It shortens as the heart speeds up, which is why the T wave sits closer to the spike in the Tachycardia scenario.
- R-R interval and heart rate
- The time from one spike to the next. Heart rate is 60 divided by the R-R interval in seconds, so 0.8 seconds between beats is 75 bpm. On standard ECG paper running at 25 mm per second, each large square is 0.2 seconds, so 300 divided by the number of large squares between two spikes gives the rate.
A normal sinus rhythm, the rhythm set by the heart's natural pacemaker in the sinus node, has a P wave before every QRS, a QRS after every P wave, a steady PR interval, and a rate of about 60 to 100 bpm in a resting adult. A little speeding up on the in-breath and slowing on the out-breath is normal, especially in younger people. It is called sinus arrhythmia, and the Stable scenario has a touch of it.
The rhythms in this simulator
| Rhythm | Rate | What to look for |
| Normal sinus rhythm | 60–100 | A P wave before every spike, evenly spaced beats. |
| Sinus tachycardia | Over 100 | Normal shapes packed close together; at high rates the P wave can merge into the T wave before it. Exercise, fever, pain, fear, blood loss, and dehydration can all cause it. |
| Sinus bradycardia | Under 60 | Normal shapes with long gaps between them. Common in fit athletes and during sleep; it can also come from medicines or a conduction problem. |
| Atrial fibrillation | Varies, often fast | No P waves, a wavering baseline, and spacing that follows no pattern at all, often described as irregularly irregular. |
| PVC | One beat | An early, wide, tall beat with no P wave in front of it. Occasional premature ventricular contractions are common in healthy people. |
| Ventricular fibrillation | None | Chaotic waves of changing size and no QRS. The ventricles quiver instead of pumping, so there is no pulse. It needs immediate CPR and defibrillation. |
| Asystole | 0 | A nearly flat line: no electrical activity. It is treated with CPR and adrenaline (epinephrine), not with a shock. |
How to read the numbers on a patient monitor
- HR (heart rate)
- Beats per minute, counted from the ECG. A typical resting adult rate is 60 to 100. The monitor averages several beats, so the number lags the trace slightly, and in atrial fibrillation it jumps around because every gap is different.
- SpO2 (oxygen saturation)
- The share of the haemoglobin in the blood that is carrying oxygen, measured by a clip on a finger or ear that shines red and infrared light through the skin. Healthy people usually read 95 to 100 percent at sea level; below about 90 is low, and many monitors alarm there. The reading lags by several seconds, and cold hands, movement, nail varnish, and poor circulation can all throw it off. Studies have also found that pulse oximeters can overestimate saturation in people with darker skin.
- Pleth (plethysmograph)
- The wave behind the SpO2 number. It shows the pulse as the blood volume in the finger rises and falls with each beat. A clean, regular wave means the number can be trusted; a flat or ragged one means it is doubtful.
- PR (pulse rate)
- The heart rate counted from the finger clip instead of from the ECG. The two normally match. When they don't, either some beats are too weak to send a pulse as far as the finger or a sensor has slipped.
- NIBP (non-invasive blood pressure)
- Measured by an arm cuff that inflates above the systolic pressure, then lets the air out in steps while it senses the pulsing of the artery underneath. The result is systolic over diastolic in millimetres of mercury: the peak pressure while the heart contracts over the lowest pressure between beats. The number in brackets is the mean arterial pressure, roughly the diastolic plus a third of the difference. Because the cuff only measures every few minutes, the reading can be out of date, which is why patients in intensive care often have a line in an artery for a continuous pressure trace.
- RR (respiratory rate)
- Breaths per minute, typically 12 to 20 for a resting adult. Many bedside monitors measure it through the ECG electrodes: they pass a tiny current across the chest and sense the change in impedance as the lungs fill. That is why a loose ECG lead can lose the breathing trace as well. Press L to see it happen.
- TEMP (temperature)
- Body temperature, from a probe on the skin, in the mouth, or elsewhere. Normal is roughly 36.5 to 37.5 °C (97.7 to 99.5 °F), and 38 °C (100.4 °F) or higher is usually counted as a fever.
Alarms and their colours
Hospital monitors sort alarms by urgency. The international standard for medical alarm systems, IEC 60601-1-8, sets out three priorities, and most monitors show them the same way. Red is high priority, a condition that needs someone now: a lethal rhythm, no breathing, or very low oxygen. Yellow is medium priority, a reading outside its limits, such as a heart rate over 120 or SpO2 under 90. Cyan or white is for low-priority advisories and technical notices. Each priority has its own sound pattern, so staff can tell from down the corridor how urgent an alarm is.
Monitors alarm often, and mostly for harmless reasons such as a patient moving or a sensor slipping. Staff becoming desensitised to the noise, known as alarm fatigue, is a recognised patient-safety problem, and hospitals spend real effort tuning alarm limits to cut false alarms.
Why the TV flatline is dramatised
On screen, the line goes flat, a long continuous tone sounds, someone shouts "clear", and the paddles bring the patient back. Nearly every part of that is changed for drama.
- A flat line is most often a loose lead. When an electrode falls off or a cable comes out, the ECG goes flat or blank. Real monitors show a leads-off message when they can detect it, and staff are trained to look at the patient, check the leads, and confirm the flat line in a second lead before believing it. Press L to compare.
- Real monitors don't hold a steady tone. They repeat the pulsed high-priority alarm. The continuous tone is a sound-design convention.
- A flat line can't be shocked back. Defibrillation works by stopping chaotic electrical activity, ventricular fibrillation or pulseless ventricular tachycardia, so the heart's own pacemaker can take over again. In asystole there is no activity to reset. Resuscitation guidelines treat it with CPR, adrenaline (epinephrine), and a search for the cause. This prop's shock works from any rhythm only because that is what scripts ask for.
- Survival is far lower than on television. A 1996 study in the New England Journal of Medicine looked at resuscitations in three US television shows, including the dramas ER and Chicago Hope, and found that 75 percent of the patients survived the arrest itself. For real cardiac arrests outside hospital, the share who survive to leave hospital is closer to one in ten.
- Patients rarely sit up and talk. Even a successful resuscitation is usually followed by days in intensive care.
If someone collapses and is not breathing normally, call your emergency number and start chest compressions. A public defibrillator (AED) checks the rhythm itself and only lets you shock when a shock will help.
Using it on set and on stream
- Click ⛶ FULLSCREEN on the screen that will be in shot. The black background and bright traces film well; set the display's brightness to suit the scene's lighting.
- If the screen shows banding or flicker on camera, try a shutter speed that matches the mains frequency and the screen's refresh rate (1/50 or 1/60 of a second), or turn the screen's brightness up.
- Cue the drama from the keyboard: 5 when the patient crashes, S when the actor shocks, and Space to freeze a frame. A wireless keyboard keeps the operator out of shot.
- Add
?scenario=arrest or another scenario to the address to open the page in the state you need. The Story loop is designed for long ambient recordings.
- For OBS, add the page as a browser source; see the streaming toolkit for setup.
Good uses
Background screens for films, short films, series, and music videos set in a hospital or a sci-fi medical bay; props for theatre, haunted houses, Halloween parties, and escape rooms; backdrops for horror streams and medical-drama video essays; a visual aid for first-aid and science lessons, as long as the class knows it is simplified; and long ambient videos of a monitor beeping quietly through the night.
Keyboard shortcuts
- F: toggle fullscreen
- V: play the video version (when available); Esc goes back
- Space: freeze or unfreeze the screen
- S: shock the patient back to a stable rhythm
- M: sound on or off (off when the page opens)
- A: pause the alarm sounds for two minutes
- N: start or stop a blood pressure measurement
- L: disconnect or reconnect the ECG leads
- 1–6: Stable, Tachycardia, Bradycardia, AFib, Cardiac arrest, Story loop
Frequently asked questions
Is this a real heart monitor?
No. It is a simulation and a visual prop, not a medical device. It does not measure anything: every trace and number is generated in your browser from simple rules, and the monitor brand, the ward, and the patient are invented. Don't use it to watch over anyone or to check your own health, and don't take anything on this page as medical advice.
How do I make the patient flatline?
Press 5 or choose Cardiac arrest from the SCENARIO menu. The ECG goes into ventricular fibrillation for about 30 seconds, fades to a flat line (asystole) roughly 50 seconds in, and stays flat until you shock or pick another scenario. Add ?scenario=arrest to the address to open the page already in arrest.
How do I bring the patient back?
Press S or click SHOCK. The trace jumps with a defibrillator artifact and the monitor returns to a normal sinus rhythm, with the heart rate settling and the oxygen level climbing back over about half a minute. It works from any rhythm, flatline included, because that is what scripts ask for. In a real hospital a flat line is not shocked.
Why is there no beep?
Sound is off until you turn it on, so the page never plays audio by surprise. Press M or click SOUND OFF to hear the heartbeat beep and the alarm tones, and press A to pause the alarm tones for two minutes. Sound stops while the screen is frozen or the video version is playing.
Can I use it in a film, music video, or stream?
Yes. It is free to use in films, music videos, theatre, streams, escape rooms, and haunted houses. Click FULLSCREEN, or add the page as an OBS browser source. The monitor brand on screen is invented, so no real manufacturer's logo ends up in shot, and the scenario is kept in the address bar, so a copied link reopens the same setup.
Does it work offline?
Once the page has loaded, the simulation makes no further network requests, so it keeps running if the connection drops. The optional VIDEO view streams from YouTube and needs a connection.
Related tools
Build out the rest of the set with the futuristic tech dashboard for a sci-fi medical bay, or the rocket launch control console for a flight surgeon's station. When the hospital's network is the thing in trouble, cut to the system breached screen, and for a trading-floor heart attack, put the fake stock exchange screen on the next monitor.